Product Details:
Material | Standard |
Weight | Standard |
Usage/Application | Standard |
Power Supply | Standard |
Country of Origin | Made in India |
Deal | in new only |
We are a leading firm in the industry involved in offering a beautiful range of Medical Air Mattress to our respected clients. Finding application in various sectors, these desks are used as bedding by blowing air and add comfort to the ailing patients. Some of its special features include made using optimum quality component for exceptional finish and lasting usage.
Features:
Ease of use
Decreasing the pressure on body
High comfort
Product Details:
Parameter Measures | SpO2 + Pulse Rate |
Display Mode | 3 Display Modes |
Model Name/Number | Standard |
Display Type | Single Color LED |
Oximeter Accuracy | Standard |
Weight | Standard |
Please send details, quotation for ''MMED 200 Pulse Oximeter.
We,
Sun Shine Medical Equipment Guard LLP is providing the wide range of medical instruments to our client as per the requirements |
Product Details:
Capacity | 5 LPM |
Operation Mode | Portable |
Operation | Electrical |
Warranty | 2 year |
Material | indian |
Color | white |
Is It Portable | Portable |
Condition | New |
We are offering a wide collection of Oxygen Concentrator which known for unique pressure swing adsorption technology. These products are designed by well trained professionals making use of the high quality material that is procured from the certifiedsuppliers of the industry. We are providing these products to our esteemed clients in varied specifications according to their predefined requirements.
Features:
Power failure alarm
Rigid design
Long functional life
Specifications:
Timer: total working hours of the unit
Present working hours
Timer for 30/60/90/120 min - the unit shall stop by the time over
Product Details:
Number of Doors | Single door |
Size | Vertical |
Power Consumption | Standard |
Type | Front Opening |
Brand | Voltas |
Capacity | 300 L |
Temperature Range | Standard |
We avail a best quality of Deep Freezer to our clients as per the requirements needed by them. They are designed in such a way that they help the user to fix or remove freezing frames. There are different types of colors and sizes available in the market of these deep freezers. They are made up of silica gel with the electronic material present inside them.
Get Best Price Of Voltas Vertical Deep Freezer For Rs.40000/-
Product Details:
Minimum Order Quantity | 10 Unit |
Operation Mode | Semi-Automatic |
Usage/Application | Agriculture |
Material | Mild Steel |
Capacity | Standard |
Pump Type | Piston Pump |
Country of Origin | Made in India |
Sun Shine Medical Equipment Guard LLP is providing the wide range of medical instruments to our client as per the requirements |
Product Details:
Thickness | Standard |
Model Name/Number | Standard |
Type | Ortho Mattress |
Size/Dimension | Standard |
Color | White |
Usage/Application | Standard |
Material | EPE+ Foam |
Box Size: 34*18*23cm N.W.: 3.0kgs G.W.: 3.5kgs Using Life: 30000hours
Mattress Specification:
1. Material: PVC 3PLY
2. Thickness: 0.3-0.4mm
3. Size: 200CM*90CM*7CM( inflated)
Pump Specification:
1. Size: 24*13*9cm
2. Weight: 1.0kgs
3. Voltage: AC 220/230V
4. Frequency: 50HZ/60HZ
5. Power: 10W
6. Pressure range: 15-20kpa (115-150mmHg)
7. Air output:4.5-5.5L/minute
8. Cycle time: 10 minutes
9. Controlled by microcomputer
10. Spare pcs: 10pcs of round material slices, 1bag of special glue
Product Details:
Parameter Measures | SpO2 + Pulse Rate |
Display Mode | 3 Display Modes |
Display Type | Single Color LED |
Oximeter Accuracy | Standard |
Weight | Standard |
Country of Origin | Made in India |
Please send details, quotation for ''Fingertip Pulse Oximeter''
Product Details:
Usage/Application | Hospital |
Mask Type | Standard |
Material | Silicone |
Size | Standard |
Color | Standard |
Type | Standard |
CPAP Nasal Pillow Mask
This product is not available in USA & Germany.
Less Weight, More Comfort
Fealite is much lighter than general nasal masks. It is quieter and offers minimal contact to the face, providing a more comfortable experience and making therapy easy to accept.
Product Details:
Parameters Measured | Temperature, ECG |
Type of display | LCD |
Display Size | Standard |
Suitable For | Adult |
Model | Standard |
Country of Origin | Made in India |
Features:
High resolution 4.3" color LCD screenCompact and portable, allowing for uninterrupted monitoringAC power supply, with built-in lithium batteryAdjustable audible and visual alarmsStorage and review of patient's trend data up to 36 hoursApplicable to adult, pediatric and neonatal patientConvenient and quick in inquiring measurement dataUSB data uploadOptional: printing
Performance:
Sp02 monitoring
Continuous real-time measuring.Adopt digital Sp02 technology, which has strong
anti-interference capability.Real-time display Sp02, pulse rate, Sp02 Plethysmogram,
bar graph, Sp02 and Pulse rate(PR) trend graph.
Trend graph with the function of adaptive scaling
Standard adult finger-clip probe, binding probe for neonatal is optional.
Sp02 Measuring
Range: 35%~100% (Resolution: 1%)
Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.
Pulse Rate Measuring
Range: 30bpm~250bpm(Resolution: 1bpm)
Accuracy: ±2bpm or ±2%, whichever is greater.
Measurement Performance in Weak Filling Condition: Sp02 and pulse rate can be shown
correctly when pulse-filling ratio is 0.4%, Sp02 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater. Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darKroom is less than ±1%.
Product Details:
Parameter Measures | SpO2 + Pulse Rate |
Display Mode | 3 Display Modes |
Display Type | Single Color LED |
Oximeter Accuracy | Standard |
Weight | Standard |
Country of Origin | Made in India |
Please send details, quotation for 'Choicemmed Fingertip Pulse Oximeter
Product Details:
Material | Mild Steel |
Usage/Application | Operation Use |
Positioning | Wall-Mounted |
Features | Standard |
Automation Grade | Automatic |
Oxygen Flush | Standard |
Product Details:
Minimum Order Quantity | 5 Piece |
Machine Condition | New |
Working Mode | Real-Time Mode |
Frequency | 1MHz |
Ultrasound Intensity | <10mW/sq. cm |
FHR Measuring Range | 50-210 bpm |
FHR Resolution | 1bpm |
FHR Accuracy | 1bpm |
FD-101CR ultrasonic fetal doppler meets the fetus daily check and routine examination at home, clinic,community and hospital.
● Easy and convenient operation
● High-fidelity, crystal clear sound
● Earphone and speaker are feasible
● High sensitivity doppler probe
● Low ultrasound dosage
● Display with backlight LCD
● Unique ergonomic design
● Average Mode, Manual Mode, Alarms for FH
Technical Specification
● Ultrasound frequency: 2MHz
● Ultrasound intensity: <10mW/cm2
● Power supply: DC Ni-Mh rechargeable battery
AC 220/110V, 50/60Hz
● Display: 45mm×25mm LCD
● FHR Measuring range: 50~240bpm
● FHR resolution: 1bpm
● FHR accuracy: ±1bpm
● Power consumption: <1W
● Dimension :135mm ×95mm ×35mm
● Weight:500g
Configuration
● Main body
● 2MHz probe
● Ni-Mh battery
● Adaptor
Product Details:
Model Name/Number | Standard |
Tidal Volume | Standard |
Patient Age Group | Neonatal |
Plateau (%) | Standard |
Mounting Type | ICU |
Inspiratory/Expiratory (I:E) Ratio | Standard |
Respiratory Rate and Minute Ventilation Volume can be independently regulated at random to meet various patients' requirements.Manual Ventilation Mode, PEEPThe airway pressure can be shown directly and reduced automatically.Air-Oxygen MixerLow-pressure AlarmAssistant Ventilation Mode can support oxygen for patients’ inspiratory
effort by automatic flow trigger
Standard configuration
Ventilator ( including air-oxygen mixer, automatic airway pressure relief valve ), small oxygen cylinder, portable bag, laryngoscope, phlegm suction pot, humidifier, airway opener, extension line, oxygen refill fitting, wrench, face mask, nasal oxygen canula, endotracheal tube.
Physical parameters
Weight of Main Device
0.70kg
Volume of Main Device
178×46×68mm
Weight of Gas Cylinder
2.5kg
Volume of Gas Cylinder
2L
Main technical indicator
Breathing Mode
IPPV Mode; A/C Ventilation; Manual Ventilation; PEEP
Operating Pressure
0.35--0.40 MPa
Minute Ventilation Volume
4--25L/min(Adjustable in succession)
Respiratory Rate
10-60 times/min (Adjustable in succession)
Seven Indication: 10,15,20,30,40,50,60 times/min
I /E Ratio
1:2
Oxygen Concentration
≤60
Inspiratory Trigger
≤-1Kpa (±50Pa)
Low Pressure Alarm
≤0.25 MPa
High Pressure Pause
0.9-1.1 MPa
Reverse Flow Pressure of Airway
≤6 KPa
Noise of Main Device
65dB
Supply Flow of Gas Cylinder
60 L/min
Continuous Working Time of Cylinder
Around 90min
Oxygen Storage Pressure for Cylinder
14.7 MPa
Oxygen Consumption
Adult ≤ 2 Cylinders/24h
Cylinder Specification: 12250 Kpa/40L
Protective Function
Airway Pressure Display
Visual
Low Pressure Alarm
Warning when supplied air pressure drops below 2.6bar
Airway Pressure Release Valve
Reducing pressure automatically when airway pressure exceeds 50cmH2O
High Pressure Protection
When supplied air pressure is over the working pressure, the ventilator will stop working following audible alarm voice.
(Respiratory Rate, Minute Ventilation Volume, I:E Ratio, Oxygen Concentration, Inspiratory Trigger are subject to a tolerance of ±15%)
Product Details:
Model Name/Number | Standard |
Usage/Application | Hospital |
Material | Plastic |
Frequency | Standard |
Speed | Standard |
Deal | in new only |
Sun Shine Medical Equipment Guard LLP is providing the wide range of medical instruments to our client as per the requirements |
Product Details:
Type Of Tens Unit | Combination |
Frequency | Standard |
Modes Of The Tens Unit | Standard |
Usage/Application | Clinical |
Material | Standard |
Intensity | Standard |
Gemisonic Ultrasound
Bag Model / Table Model -Solid State
This unit is deigned to generate Ultrasonic waves for effective treatment of neuromuscular diseases. The Combination of the thermal effect and the mechanical effect on the tissues produces micro-massage as well as chemical effect on membrane permeability.
Accessories
1. One mains cable with receptacle
2. One Transducer (Sound head) for treatment
Specification:
Power Output
Continuous - 15 watts, Pulsed-21 watts
Frequency
230 Volts 50 c/s AC.
Dimensions
240x220x140 mm. Table model
320x210x80 mm , Bag Model
Weight
2.8 kg Table Model
2.5 kg Bag Model
Product Details:
Usage/Application | Clinical Purpose |
Operation Mode | Portable |
Size | Compact |
Power Consumption | Standard |
Medication Cup Capacity | Standard |
Country of Origin | Made in India |
Portable Ultrasonic Nebulizer C517
Complement the water of your skin rapidly, keep the skin softness and harmony
Take care of your respiratory tract, improve the immune response
Eliminate the harmful substance
Suitable for all ages, for treatment of cold, Bronchial Asthma and other respiratory illness.
Specification:
Carton Dimension: 39.0*29.5*45.0(CM)
Droplet Size: 0.5 Micron – 5 Microns
Unit Dimension: 14.0x8.0x5.5(CM)
Unit Weight: Approx. 8 ounces
Medication Cup Capacity: 10 ml
G. W.: 10.5KGS
N.W.: 10KGS
Package: 10PCS/CTN, 549 CTNS per 20FT
Product Details:
Usage/Application | Clinical Purpose |
Operation Mode | Portable |
Size | Compact |
Power Consumption | Standard |
Medication Cup Capacity | Standard |
Country of Origin | Made in India |
Product Details:
Parameters Measured | RESP, Temperature, ECG |
Type of display | LCD |
Display Size | Standard |
Suitable For | Adult |
Model | Standard |
No of Leads in ECG | 3 |
Country of Origin | Made in India |
ln-hospital application include emergency, pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor and hospital-based special procedure areas
Advanced streamline outline design, compact, lightweight, in-built handle makes it truly portableCan be used to monitor adult, pediatric & neonate patientLow perfusion working possibleVarious display screen : Trend Coexist Display, OxyCRG Dynamic View Display, Bed to Bed view DisplayArrhythmia Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S-T segment analysis, pacemaker detection Drug calculation and titration tableNetworking capacity and nurse call systemLarge volume of tabular and graphic trends information storage and easy to recallCapture dynamic waveformsIn-built Rechargeable battery which provides a backup time of upto 4 hoursUser friendly menu structure with easy to use rotary dialProtection Against electrosurgical interference and defibrillationIntelligent audio and visual comprehensive alarm. Volume adjustment possible
Standard Configuration : ECG, HR, Sp02, ST Analysis, Resp, NIBP, 2* Temp, Drug Dose Calculator, built in battery
Optional Configuration : Recorder, 2*IBP, EtC02 (Main Stream or Side Stream)
TECHNICAL SPECIFICATIONS
ECG
Lead Mode : 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform : 2 ch
Lead mode: 3 Leads ( R, L, F or RA, LA, LL) Lead selection : I, II, III, Waveform : 1 ch
Gain: 2.5mm/mV, 5.0mm/mV, lOmm/mV, 20mm/mV, auto
HR Alarm Range
Adult: 15 ~ 300 bpm
Neo/Ped : 15 ~ 350 bpm
Accuracy : ± 1% or ± 1 bpm,which great
Resolution : 1 bpm
Bandwidth
Surgery : 1 ~ 15 Hz
Monitor : 0.5 ~ 35 Hz
Diagnostic : 0.05 ~ 100 Hz
ST Segment Monitoring Range : Measure and Alarm -2.0 ~ 2.0 mV
ARR Detecting
Type : ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
RESPIRATION
Method : R-F(RA-LL) Impedance
Resp. Rate Measuring and Alarm Range
Adult : 0 ~ 1 20 rpm
Neo/Ped : 0 ~ 150 rpm
Resolution : 1 rpm
Accuracy : ±2 rpm
Apnea Alarm : 10 ~ 40s
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type : SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS: 40 ~ 270 mmHg
DIA: 10 ~ 215 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric Mode
SYS: 40 ~ 200 mmHg
DIA: 10 ~ 150 mmHg
MEAN: 20 ~ 165 mmHg
Neonatal Mode
SYS: 40 ~ 135 mmHg
DIA: 10 ~ 100 mmHg
MEAN: 20 ~ 1 10 mmHg
Resolution Pressure: lmmHg
Accuracy Pressure Maximum Mean error : ±5 mmHg
Overpressure Protection
Adult Mode: 297±3 mmHg
Pediatric Mode: 240±3 mHg
Neonatal Mode: 147±3 mmHg
Sp02
Measuring Range : 0 ~ 100 % Alarm Range : 0 ~ 100 % Resolution : 1 %
Accuracy : 70% ~ 100% ±2 %
0% ~ 69% unspecified
Pulse Rate
Measuring and Alarm Range: 20~300bpm
Resolution: 1 bpm
Accuracy: ±2bpm
Temperature
Channel: 2
Measuring and Alarm Range: 0 ~ 50°C
Resolution: 0.1 °C
Accuracy: ±0.1 °
Product Details:
Parameters Measured | ECG, RESP, Temperature |
Type of display | LCD |
Display Size | Standard |
Suitable For | Adult |
Model | Standard |
Country of Origin | Made in India |
In-hospital application include emergency, pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor and hospital-based special procedure areas
Advanced streamline outline design, compact, lightweight, in-built handle makes it truly portableCan be used to monitor adult, pediatric & neonate patientVarious display screen : Trend Coexist Display, OxyCRG Dynamic View DisplayArrhythmia Analysis, pacemaker detection, Networking capacity and nurse call systemLarge volume of tabular and graphic trends information storage and easy to recallIn-built Rechargeable battery which provides a backup time of upto 4 hoursUser friendly menu structure with easy to use rotary dialProtection Against electrosurgical interference and defibrillationIntelligent audio and visual comprehensive alarm. Volume adjustment possible7 inch high resolution color TFT LCD display 50°CPatient into input management function
Standard Configuration : ECG, HR, Sp02, ST Analysis, Resp, NIBP, built in battery
Optional Configuration : Recorder, IBP, EtC02 (Main Stream or Side Stream)
TECHNICAL SPECIFICATIONS
ECG
Lead Mode : 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Waveform : 1 ch
Gain: 2.5mm/mV, 5.0mm/mV, l0mm/mV, 20mm/mV,
HR Alarm Range
Adult: 15 ~ 350 bpm
Neo/Ped : 15 ~ 350 bpm
Accuracy : ± 1% or ± 1 bpm,which great
Resolution : 1 bpm
Bandwidth
Surgery : 1 ~ 20 Hz
Monitor : 0.5 ~ 40 Hz
Diagnostic : 0.05 ~ 130 Hz
ST Segment Monitoring Range : Measure and Alarm -2.0 ~ +2.0 mV
RESPIRATION
Method : R-F(RA-LL) Impedance
Resp. Rate Measuring and Alarm Range
Adult : 0 ~ 1 20 rpm
Neo/Ped : 0 ~ 150 rpm
Resolution : 1 rpm
Accuracy : ±2 rpm
Apnea Alarm : 10 ~ 40s
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type : SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS: 40 ~ 270 mmHg
DIA: 10 ~ 215 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric Mode
SYS: 40 ~ 200 mmHg
DIA: 10 ~ 150 mmHg
MEAN: 20 ~ 165 mmHg
Neonatal Mode
SYS: 40 ~ 135 mmHg
DIA: 10 ~ 100 mmHg
MEAN: 20 ~ 110 mmHg
Resolution Pressure: lmmHg
Accuracy Pressure Maximum Mean error : ±5 mmHg
Overpressure Protection
Adult Mode: 297±3 mmHg
Pediatric Mode: 240±3 mHg
Neonatal Mode: 147±3 mmHg
Temperature
Channel: 1
Measuring and Alarm Range: 0 ~ 50°C
Resolution: 0.1 °C
Accuracy: ±0.1 °C
Product Details:
Model Name/Number | Standard |
No. of Leads | 5 |
Type of Display | LED |
Patient Type | Adult |
Pulse Rate Range | 20-200 bpm |
12 Lead Interpretation | Yes |
Number of leads analyzed in single time | 3 |
ECG-5000 12 Channel Holter
ECG Monitoring System
Introduction:
The ECG5000 Holter system is composed of the ECG recorders, a computer system, a laser printer and the software. The recorder has build-in flash storage media that increases its memory capacity. The sampling rate of 1000 sampling/sec has improved the quality of waveform. The software of the system is checked by AHA and MIT data, which ensure its accuracy.
Features:
Windows software interface
Quick and accurate analyzing system
Special editing system of R point
Perfect analysis function of ST segment
The analysis function of T wave of all.channels and T wave trend graph
Review of the ECG trend graph
The analysis system of HR variability, providing the regular SDNN, SDANN, RMSSD, LF, HF, time domain, and frequency domain
QT analysis and QT trend graph
Acquire pacing ECG directly without separate channel, also have the functions of VCG,LPG, high frequency ECG, FCG. (option)
Recorder:
12 Channel Synchronized ECG AcquisitionSmall ECG recorder with OLED color screen which can display real time ECG waveform and review storage data.Capacity is up to 2GSelectable sampling rate, 200, 500, 1000 sampling/secSampling accuracy : 12 bitBuild-in FLASH storage media, which can refrain the flash card from damage by repeatedly inserted and pull out
USB interface
Inside The Box
1 Holter recorder1 CD of software10 pieces of patient cable10 pieces of disposable ECG sensor1 porch for hanging recorder1 USB cable for data downloadInstruction Manual1 year warranty
Product Details:
Type | Digital Thermometer |
Temperature Range | Standard |
Accuracy | Standard |
Response Time | Standard |
Model | Standard |
Flexible Tip | Standard |
MC-720
Quick Measurement Temperature Measurement25 Memories Storage LCD Screen Buzzer
Product Details:
Type | Digital Thermometer |
Temperature Range | Standard |
Accuracy | Standard |
Response Time | Standard |
Model | Standard |
Country of Origin | Made in India |
MC-246
RectalWaterproofBuzzerMemory
We,
Sun Shine Medical Equipment Guard LLP is providing the wide range of medical instruments to our client as per the requirements |
Product Details:
Model Number | Standard |
Accuracy | 0.02 pressure |
Cuff Type | Standard |
Weight | Standard |
Measurement Range (Pressure) | Standard |
Usage/Application | Hospital |
JPN1
Blood Pressure Level IndicatorDetects irregular heartbeatBody Movement Indicator
Product Details:
Model | Standard |
No. of Films | 2 |
Dimensions (L x H) | Standard |
Thickness | 45 mm |
LED Intensity | Standard |
Weight | Standard |
Features:
•Metal Frame Plastic sheet
•Conventional fluorescent tubes
•Single Film Dimension: 450 W x 600 H x
•100 D mm approx
•Double Films Dimension: 900 W x 600 H x
•100 D mm approx
Additional Information:
Product Details:
Capacity(Litre per minute) | 3 LPM |
Model Name/Number | Standard |
Product Type | Portable |
Weight (in kg) | Standard |
Oxygen Concentration | Standard |
Outlet Pressure | Standard |
• Pressure swing absorption technology.
• Adjustable timer with LCD display.
• No consumables required.
• Alarms, Power failure, temperature, low and high pressure.
• Adjustable flow rate, Continuous flow of oxygen allows quiet and restful sleep to patients.
• Inbuilt Nebulizer.
Product Details:
Type | ALS Defibrillators |
Usage/Application | Home & Public Place |
Operation Mode | Manual |
Accuracy | Standard |
Atmospheric Pressure Range | Standard |
Is It Battery Backup | Battery Backup Available |
Is It LCD Display | LCD Display |
Product Details:
Shape | Square |
Size | Standard |
Weight | Standard |
Power | Standard |
Temperature | Standard |
Tank Size | Standard |
Paraffin Wax Bath
Portable Double walled, effectively insulated steel tank with cover, castors and automatic thermostat control.
Power control in three steps. Thermostat 0 to 100° c
Neon Lamp for Main power & thermostat Control.
Wooden frame on top outer cover oven beck paint
Minor Size: 12"x12"x8"
Major Size: 22"x16"x12"
Product Details:
Parameters Measured | ECG |
Type of display | LCD |
Display Size | Standard |
Model | Standard |
Pulse Rate Range | 20-200bpm |
Country of Origin | Made in India |
MULTIPARA MONITOR EVA-N
ln-hospital application include emergency, pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor and hospital-based special procedure areas
Advanced streamline outline design, compact, lightweight, in-built handle makes it truly portableCan be used to monitor adult, pediatric & neonate patientLow perfusion working possibleVarious display screen : Trend Coexist Display, OxyCRG Dynamic View Display, Bed to Bed view DisplayArrhythmia Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S-T segment analysis, pacemaker detection Drug calculation and titration tableNetworking capacity and nurse call systemLarge volume of tabular and graphic trends information storage and easy to recallCapture dynamic waveformsIn-built Rechargeable battery which provides a backup time of upto 4 hoursUser friendly menu structure with easy to use rotary dialProtection Against electrosurgical interference and defibrillationIntelligent audio and visual comprehensive alarm. Volume adjustment possible
Standard Configuration : ECG, HR, Sp02, ST Analysis, Resp, NIBP, 2* Temp, Drug Dose Calculator, built in battery
Optional Configuration : Recorder, 2*IBP, EtC02 (Main Stream or Side Stream)
TECHNICAL SPECIFICATIONS
ECG
Lead Mode : 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform : 2 ch
Lead mode: 3 Leads ( R, L, F or RA, LA, LL) Lead selection : I, II, III, Waveform : 1 ch
Gain: 2.5mm/mV, 5.0mm/mV, lOmm/mV, 20mm/mV, auto
HR Alarm Range
Adult: 15 ~ 300 bpm
Neo/Ped : 15 ~ 350 bpm
Accuracy : ± 1% or ± 1 bpm,which great
Resolution : 1 bpm
Bandwidth
Surgery : 1 ~ 15 Hz
Monitor : 0.5 ~ 35 Hz
Diagnostic : 0.05 ~ 100 Hz
ST Segment Monitoring Range : Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type : ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Product Details:
Usage/Application | Laboratory |
Brand | Sun Shine |
Model Name/Number | Standard |
Color | White |
Display | Standard |
Frequency | Standard |
We,
Sun Shine Medical Equipment Guard LLP is providing the wide range of medical instruments to our client as per the requirements |
Product Details:
Feature | Contactless |
Model Name/Number | Standard |
Temperature Range | Standard |
Battery Life | Standard |
Country of Origin | Made in India |
Deal | in new only |
TH-839S
Quick MeasurementFever AlarmFahrenheit to CelciusErgonomic Design
Product Details:
Machine Condition | New |
Imaging Mode | 3D/ 4D |
Doppler Mode | Color Doppler Velocity |
Type of Transducer/ Probe | Convex |
Clinical Application | General Imaging |
Is It Portable | Portable |
Vascular Doppler BT-200V
Functions
• Sound from built-in speaker
• 4,5,8MHz Doppler available
Features:
• Compact and Light
• High-Sensitivity Doppler probe
• Ergonomic Design
• Clean Sound
• Easy to Use
• Low power Consumption
• Long Time to Continuous Use (6hours)
Specifications:
• Display
- LCD
- Low Battery Display
- Signal Quality Display
•Heart Rate Range
- 50~240
•Accuracy
- ±2%
• Ultrasound Frequency
- 2,4,5,8 Mhz
•Ultrasound Intensity
- <10mW/cm²
• Speaker Output Power
- 1.2W(Built-in Loudspeaker)
• Audio output for earphone
• Auto Shut-off
- 5 minutes
• Auto Shut-off on signal
- 1minute
• Power
- 1.5V Battery X 2 (Type: AA)
• PC Interface
- Sound Card
• Battery Life
- 360 minutes
• Accessories
- Carrying Case
- Battery (1.5V AA X 2)
- Gel
Product Details:
Material | Plastic |
Model Name/Number | Standard |
Brand | Sun Shine |
Diameter | Standard |
Display Type | Standard |
Country of Origin | Made in India |
Sun Shine Medical Equipment Guard LLP is providing the wide range of medical instruments to our client as per the requirements |
Product Details:
Country of Origin | Made in India |
Deal | in new only |
SPECIFICATIONS:
Environmental Conditions
Operating temperature: +5°C to +40°C
Operating humidity: 0%-93 % relative humidity non-condensing
Storage and transport: - 20°C to + 55°C
Storage and transport humidity: 0%-93 % relative humidity non-condensing
NOTE: specifications subject to change without prior notice.
Product Details:
Model Name/Number | Standard |
Tidal Volume | Standard |
Patient Age Group | Adult |
Plateau (%) | Standard |
Plateau Pressure | Standard |
Country of Origin | Made in India |
Four operating modes : CMV, A/CMV, SIMV, SPONT
Lightweight, durable and simple to use
Ventilation volume and ventilation frequency can be adjusted in succession and separately
LCD graphical display to indicate airway pressure, alarm limits, tidal volume, mode
Automatic pressure relief valve for airway pressure more than 6KPa
Air-oxygen blender prolongs the operating time during long-time transportation
Audiovisual low input pressure alarm and over input pressure protection
Specification
VENTILATOR PARAMETERS
RANGE
Tidal Volume (at C mode)
50~1200 ml
Flow (at A/C, SIMV mode)
Low, Med, High
Breath Rate
5-60 bpm, 1~12 bpm for SIMV
45%~90%
Spont Flow
0~5 L/Min
Sigh
1 per 0~100 breath cycle
Inspiratory time
0.5~3 s
Trigger Level
-10~0 hpa
PIP
0~60 hpa
Silence
60s
ALARMS AND INDICATORS
High Pressure Alarm Limit
20~60hpa (to be set)
Low Pressure Alarm Limit
2~20hpa (to be set)
Alarm Indicator
Flashing Red Indicator
Over Pressure Relief
<60 hpa
Main Circuit Pressure (Paw)
-2~10kPa
ELECTRICAL SPECIFICATIONS
INPUT POWER SUPPLY
DC Voltage : 12 V
Power : 10 VA
CHARGER
AC Voltage : 100 ~ 240 V, 50/60 Hz
Power : 25 VA
PNEUMATIC SPECIFICATIONS
Oxygen Inlet
Pressuried Oxygen : 0.40 Mpa, 60 L/min.
PHYSICAL